The RMDC series can be ordered with an optional FAI input to
disable the power to selected outputs upon activation of the FAI
input. The FAI input may be wired to latch if required by local
codes and accepts a 9–30V DC voltage, NO/NC contact or open
collector for activation.
These diagrams show various wiring methods. Be sure all
internal jumpers are set properly.
RMDC Series Installation Instructions 52-376 Rev B01
– +
SYSTEM
DC
– +
FAI
DC
L V+ B A
FAI INPUT
TERMINAL BLOCK 1
REMOTE NO DRY CONTACT
+9 to 30VDC
–VDC
– +
SYSTEM
DC
– +
FAI
DC
L V+ B A
FAI INPUT
TERMINAL BLOCK 1
+9 to 30VDC
–VDC
– +
SYSTEM
DC
– +
FAI
DC
L V+ B A
FAI INPUT
TERMINAL BLOCK 1
REMOTE NC
DRY CONTACT
– +
SYSTEM
DC
– +
FAI
DC
L V+ B A
FAI INPUT
TERMINAL BLOCK 1
REMOTE NO
DRY CONTACT
REMOTE NC
RESET SWITCH
– +
SYSTEM
DC
– +
FAI
DC
L V+ B A
FAI INPUT
TERMINAL BLOCK 1
REMOTE NO
DRY CONTACT
– +
SYSTEM
DC
– +
FAI
DC
L V+ B A
FAI INPUT
TERMINAL BLOCK 1
REMOTE NO
DRY CONTACT
REMOTE NO
DRY CONTACT
Remote normally open,
dry contact trip using
external voltage source
with common return to
the FAIM. Internal FAI
mode jumper (J1) must
be set to the right.
Remote normally open,
dry contact or open
collector trip using the
internal voltage source of
the FAIM. Internal FAI
mode jumper (J1) must
be set to the right.
Remote normally closed,
dry contact trip using the
internal voltage source of
the FAIM. Internal FAI
mode jumper (J1) must
be set to the right.
Remote normally open,
dry contact or open
collector trip using the
internal voltage source of
the FAIM with latch
function Remote reset
switch is used to unlatch
FAI condition after system
alarm is restored to
normal supervisory
condition. Internal FAI
mode jumper (J1) must
be set to the right.
Remote normally open,
dry contact or open
collector trip using the
internal voltage source of
the FAIM. Internal FAI
mode jumper (J1) must
be set to the right.
Remote normally open,
dry contact trip using the
internal voltage source of
the FAIM. Internal FAI
mode jumper (J1) must
be set to the right.
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13

Comentarios a estos manuales

Sin comentarios